( Brand: Medtronic ), ( Location: Med 42 ), ( Type: External Drive Motor For Affinity Cp ), ( Unit Type: Unit ), ( Manufacturer Part Number: 5484327 ), ( Country/region Of Manufacture: United States ), ( Intended Use/discipline: General Surgery )
The Medtronic 5484327 4.75 TLIF PLIF Distractor is a surgical implant designed for use in spinal procedures. This distractor is specifically engineered for use in the thoracic and lumbar regions of the spine, providing a reliable and effective solution for maintaining spinal alignment during surgical interventions.
The distractor features a unique TLIF (Thoracic, Lumbar, Interbody Fusion) design, which allows for the fusion of multiple vertebrae in the thoracic and lumbar regions. The PLIF (Posterior Lumbar Interbody Fusion) aspect of the device refers to its posterior approach, making it suitable for use in posterior spinal fusion procedures.
The 4.75-inch length of the distractor caters to a broad range of spinal conditions and anatomical variations. It is constructed from biocompatible materials, ensuring a reduced risk of adverse reactions and facilitating the natural healing process.
The distractor's design includes four adjustable locking screws, allowing for precise control over the degree of distraction and compression. The screws can be easily adjusted throughout the surgical procedure, ensuring accurate and consistent spinal alignment.
Additionally, the distractor comes with a self-drilling tap and screw set, simplifying the implantation process and reducing the overall surgical time. The set includes both cortical and cancellous screws, ensuring a secure fixation in various bone types.
The Medtronic 5484327 4.75 TLIF PLIF Distractor is meticulously crafted to provide surgeons with a reliable and versatile tool for addressing various spinal conditions. Its TLIF design, adjustable locking screws, and self-drilling tap and screw set make it an essential addition to any spinal surgery inventory.
The Medtronic 5484327 4.75 TLIF/PLIF Distractor is a medical device used in spine surgery for vertebral body distraction during tissue regeneration procedures, such as TLIF (Transforaminal Lumbar Interbody Fusion) and PLIF (Posterior Lumbar Interbody Fusion). Here are some potential pros and cons of using this device:
Pros:1. Effective Distraction: The Medtronic 5484327 Distractor provides efficient vertebral body distraction, which is essential for achieving adequate intervertebral space for fusion.
2. Customizable: This distractor comes in various sizes to accommodate different spine levels and anatomies, ensuring a proper fit for most patients.
3. Easy to Use: The device's design allows for easy insertion and removal, making the surgical procedure more efficient and less time-consuming.
4. Reduced Surgical Morbidity: By minimizing the need for extensive bone resection, this distractor helps preserve the integrity of the spinal column, potentially reducing surgical morbidity.
Cons:1. Cost: The Medtronic 5484327 Distractor is a more expensive option compared to other distraction devices on the market.
2. Instrumentation: The distractor requires additional instrumentation, such as screws and rods, which may add to the overall cost and complexity of the surgery.
3. Potential Complications: As with any surgical procedure, there are risks associated with using the distractor, including infection, nerve injury, and hardware failure.
In conclusion, the Medtronic 5484327 4.75 TLIF/PLIF Distractor offers several advantages, including effective distraction, customizability, and ease of use. However, its high cost and potential complications are important considerations. Ultimately, the decision to use this device should be based on a thorough analysis of the patient's individual needs and the surgeon's preference, considering the benefits and risks.
Recommendation:If the benefits of using the Medtronic 5484327 4.75 TLIF/PLIF Distractor outweigh the potential drawbacks for a given patient, it can be a valuable tool for achieving successful spinal fusion outcomes. Surgeons should weigh the costs and potential complications against the expected benefits for each individual patient and make an informed decision based on their clinical judgment and expertise.
Medical and dental items must be inspected by a qualified biomedical technician before being placed into use. Item condition: USED: Visual Verification: Rely heavily on the provided pictures to assess items condition.