( Brand: Siemens ), ( Serial Number: 81201765 ), ( Functional Condition: Untested ), ( Manufacturer Part Number: 4V2C )
The Siemens 4V2C Convex Transducer is a versatile and high-performing ultrasound transducer designed for a wide range of clinical applications. This transducer is part of Siemens' advanced portfolio of diagnostic imaging solutions, delivering clear, detailed images with exceptional resolution.
The 4V2C Convex Transducer features a large, 256-element array, which enables a wide field of view and covers a broad frequency range of 2.5 to 5.5 MHz. This broadband capability allows for optimal imaging in various clinical applications, including abdominal, small parts, and obstetrics scanning.
The convex geometry of the transducer ensures excellent image quality with good penetration and uniformity, making it suitable for superficial and deep scanning. The transducer's ergonomic design includes a comfortable, easy-to-grip handle and a smooth, water-friendly surface for easy manipulation during scanning procedures.
The Siemens 4V2C Convex Transducer is equipped with advanced features, such as Tissue Harmonic Imaging (THI) and Harmonic Boost, which improve image quality by reducing noise and artifacts. THI utilizes the harmonic signals produced by the interaction of the ultrasound waves with the tissue, while Harmonic Boost amplifies these signals for enhanced image detail.
Additionally, the 4V2C Convex Transducer supports real-time scanning and offers various scan modes, including B-mode, Doppler, and color Doppler imaging. The transducer's compact size and lightweight design make it portable and convenient for use in various clinical settings.
This Siemens transducer is compatible with various Siemens ultrasound systems, ensuring seamless integration and ease of use for healthcare professionals. With its advanced imaging capabilities, ergonomic design, and versatile application range, the Siemens 4V2C Convex Transducer is an excellent choice for clinical environments seeking high-quality ultrasound solutions.
The Siemens 4V2C Convex Transducer is a commonly used ultrasound transducer with several advantages and disadvantages for medical imaging applications.
Advantages:1. Wide Coverage: The 4V2C transducer provides a large field of view, making it suitable for imaging large areas such as the abdomen and the liver. It can capture a larger image in a single scan, reducing the need for multiple scans and saving time.
2. Good Depth Penetration: This transducer is capable of penetrating deeper into the body, making it ideal for imaging deeper structures such as the kidneys and the pancreas. It can provide clear images of structures located up to 10 cm below the skin surface.
3. Good Resolution: The 4V2C transducer offers good resolution, enabling the detection of small structures and lesions. This is particularly important in the abdomen, where small lesions can be missed with lower-resolution transducers.
4. Versatile: The 4V2C transducer can be used for various imaging modalities, including B-mode, color Doppler, and power Doppler. It can also be used for both superficial and deep imaging.
Disadvantages:1. Limited Angular Coverage: The convex transducer has a limited angular coverage, making it less suitable for imaging structures that are not perpendicular to the probe. This can result in artifacts or incomplete images.
2. Limited Resolution in Depth: While the 4V2C transducer offers good resolution in the imaging plane, its resolution in the depth plane is not as good as that of linear or phased array transducers. This can make it difficult to visualize small structures located deep within the body.
3. Limited Frequency Range: The 4V2C transducer operates at a lower frequency range compared to linear or phased array transducers. This can limit its ability to detect small structures or to differentiate between different tissues.
Conclusion:The Siemens 4V2C Convex Transducer is a versatile and powerful ultrasound transducer that offers several advantages for medical imaging applications, including a large field of view, good depth penetration, and good resolution. However, it also has some limitations, such as a limited angular coverage, limited resolution in depth, and a limited frequency range.
Recommendation:The Siemens 4V2C Convex Transducer is an excellent choice for imaging large areas of the body, particularly the abdomen, and for imaging deeper structures. It is a cost-effective option for clinical settings where a versatile transducer is required. However, for more specialized applications, such as cardiac imaging or imaging of small structures, higher-resolution linear or phased array transducers may be more suitable.
Shipping cost is calculated by zip code and available at the top of page. The and photos represent best efforts to convey information our opinions about a product. Current rates are $175 for packing and pelleting each standard pallet Standard size is 48 x40 x60 $300 non-standard. $350 for packing and pelleting each custom reinforced pallet.
Reline will attempt to replace product prior issuing credit. Serial Number: 81201765.