( Brand: Waters ), ( Model: ACQUITY ), ( Type: Healthcare, Lab Dental ), ( Manufacturer Part Number: 186015043 ), ( Country Of Origin: Ireland )
The WATERS 186015043 Acquity UPLC BEH C18 2.1 x 100 mm, 1.7 m Bio Dual Detectors PDA is a high-performance, ultra-performance liquid chromatography (UPLC) system designed for accurate and efficient separation and detection of complex mixtures in various industries, including pharmaceuticals, biotechnology, and food and beverage.
This UPLC system consists of two quaternary pumps, each capable of delivering flows up to 2 mL/min. The solvent delivery system ensures precise, reproducible delivery of mobile phases with minimal carryover, allowing for reliable and consistent chromatographic separations.
The heart of this UPLC system is the Acquity UPLC BEH C18 2.1 x 100 mm, 1.7 m Bio Dual Detectors PDA column. This column is made of stainless steel with a 2.1 mm inner diameter and 100 mm length, and it features a C18 stationary phase with a particle size of 1.7 m. The column's pore size and particle size are optimized to provide fast, efficient separations while retaining excellent resolution and peak capacity.
The Bio Dual Detectors PDA component of this UPLC system is a photodiode array (PDA) detector that can detect and quantify UV absorbing compounds in the range of 190 to 800 nm. The PDA detector offers high sensitivity and accuracy, allowing for the detection of trace compounds and quantification of major components in complex mixtures. Additionally, the PDA detector's ability to record a full UV spectrum for each eluting peak enables the identification of unknown compounds and provides valuable information for structure elucidation.
The UPLC system also includes an Acquity UPLC Class H Quaternary Solvent Manager, which provides efficient solvent management and mixing capabilities. The system's software, Waters Empower 3, offers powerful data analysis tools and integration capabilities, enabling researchers to quickly and easily process and interpret chromatographic data.
Overall, the WATERS 186015043 Acquity UPLC BEH C18 2.1 x 100 mm, 1.7 m Bio Dual Detectors PDA is a versatile and powerful UPLC system designed for the most demanding analytical applications. Its high-resolution column and sensitive PDA detector make it an ideal tool for separating and detecting a wide range of compounds in a variety of industries.
The Waters 186015043 Acquity UPLC BEH C18 columns are widely used in laboratories for various types of analyses, particularly in the bio-pharmaceutical industry. These columns are compatible with Waters' Bio-Dual Detectors PDA (Photo Diode Array) and offer excellent separation capabilities. In this text, we will discuss the pros and cons of investing in these columns to help you make an informed decision.
Pros:1. Superior Separation Capabilities: The BEH C18 columns provide excellent separation efficiency and resolution for a wide range of compounds. They are suitable for both small and large molecule separations, making them versatile in various applications.
2. High Speed Chromatography: The columns are designed for high-speed chromatography, enabling rapid analysis of samples. This feature is particularly beneficial for laboratories dealing with large sample volumes or those requiring quick turnaround times.
3. Consistent Performance: The Waters Acquity UPLC BEH C18 columns offer consistent performance, ensuring accurate and reliable results. The columns are engineered to minimize column-to-column variability, ensuring that every analysis is of the highest quality.
4. Compatibility: The columns are specifically designed for use with Waters' Bio-Dual Detectors PDA. This compatibility ensures seamless integration between the column and detector, ensuring optimal performance.
Cons:1. Cost: The Waters Acquity UPLC BEH C18 columns are more expensive compared to other C18 columns from other vendors. The high cost may be a significant barrier for smaller laboratories or those with limited budgets.
2. Requires Specific Instrumentation: The columns are designed to be used with Waters' Bio-Dual Detectors PDA. This requirement may limit their usage in laboratories that do not have access to this specific instrumentation.
Conclusion:The Waters 186015043 Acquity UPLC BEH C18 columns offer superior separation capabilities, high speed chromatography, consistent performance, and compatibility with Waters' Bio-Dual Detectors PDA. However, the high cost and requirement for specific instrumentation may be drawbacks for some laboratories.
Recommendation:If your laboratory requires high-performance columns for bio-pharmaceutical analysis and has access to Waters' Bio-Dual Detectors PDA, the Waters 186015043 Acquity UPLC BEH C18 columns are an excellent investment. The columns' superior separation capabilities, consistency, and compatibility with the PDA are unparalleled. However, if cost is a significant concern, it may be worth considering other C18 column options from other vendors.
Made by Waters, a reputable brand known for producing quality laboratory equipment, this system is equipped with dual detectors enhanced detection capabilities. Originating from Ireland, this model offers reliable and accurate results for various bio analytical chromatography needs in a range of industries. Ideal for research, drug discovery, and clinical testing, the Waters ACQUITY UPLC H-Class Bio System is a versatile efficient tool biochemical analysis. The Waters ACQUITY UPLC H-Class Bio System with Dual Detectors PDA FLR is a high-performance liquid chromatography system designed for use in healthcare, lab, and dental applications.